Skip to content

Calculators

OwnHealth runs a few published formulas on the lab values a person has recorded. Each result shows its formula version, its citation and the values it used, each with its source. When a result cannot be computed, it says why. This is information, not diagnosis.

Calculator Page Inputs (one draw) Validity
eGFR, CKD-EPI 2021 creatinine ckd-epi-2021.md creatinine adults (18 and over), sex at birth recorded
eGFR, CKD-EPI 2021 creatinine-cystatin C ckd-epi-2021.md creatinine, cystatin C as above
FIB-4 fib-4.md AST, ALT, platelets age 35 and over
HOMA-IR homa-ir.md glucose, insulin same draw; says when fasting is not recorded
SCORE2, SCORE2-OP score2.md total and HDL cholesterol; systolic pressure, smoking status, country 40 to 69, and 70 to 89; apparently healthy people
PREVENT (total CVD, ASCVD) prevent.md total and HDL cholesterol; systolic pressure, smoking status, eGFR, diabetes, medicines 30 to 79, no cardiovascular disease; the published input ranges

Two more pages explain how the rule pack judges change over time in one marker. They are rules, not calculators, and their flags enter the state body:

  • rcv.md: the reference change value, its EuBIVAS CVs with their DOIs, and why a change of lab or method is not judged.
  • baseline.md: the person's usual level from 3 to 5 earlier results.

How a result is made

  • Computed on read. Nothing is stored. Each read builds the document ownhealth.calculators/v1 for one profile and one as_of day. Its calculators_hash is the sha256 of the same canonical JSON that state_hash uses. The document never enters the hashed state body.
  • One draw. All inputs of one result come from one draw: the lab report (report_key), else the document and the day, else the day. A document alone is not a draw, because a FHIR bundle or an Apple Health export with no DiagnosticReport holds values from many days. Inputs with different days are refused (inputs_not_same_draw). A formula runs once for each draw that holds all its inputs, so the kidney card can show eGFR over time. The cardiovascular risk calculators are the exception: they give one result on the day, from the newest lipid draw and the facts beside it.
  • Units. data/calculators/units.yaml lists each unit a formula accepts and the number the printed value is divided by, with its citation. A unit with no row is refused (unit_unsupported). No factor is guessed.
  • Arithmetic. Decimal arithmetic (rust_decimal, with exp and ln), never floating point. The value is rounded to the precision in data/calculators/calculators.yaml.
  • Refusals. A result that fails a validity rule has status refused. A missing input gives not_assessed. Neither carries a value. The reason codes are missing_input, inputs_not_same_draw, not_adult, age_below_35, sex_not_recorded, birth_date_not_recorded, unit_unsupported, not_a_number (a value printed as < 0.3, or text) and out_of_range. The cardiovascular calculators add age_out_of_range, country_not_recorded, region_not_covered, outside_score2_scope, outside_prevent_scope, egfr_below_60, marked_risk_factor and input_out_of_range.

Where to read it

  • REST: GET /api/profiles/{p}/calculators?as_of=&lang=, with scope read:labs.
  • MCP: the resource ownhealth://profile/{id}/calculators, with scope read:labs. There is no tool. A token in minimal identity mode reads every date relative to as_of, as in the tool answers.
  • UI: the Calculators card on a biomarker page lists every calculator that reads that marker. The Related markers card of a kidney or liver marker also shows the computed eGFR or FIB-4.

How the numbers are checked

server/crates/ownhealth-rules/tests/fixtures/calc/*.json holds vectors. Each file names its source: the R package kidney.epi 1.4.0 for CKD-EPI 2021, the paper's formula for FIB-4 and HOMA-IR, the papers' examples through RiskScorescvd 0.3.1 for SCORE2 and SCORE2-OP, and the supplement and preventr 0.12.2 for PREVENT (tests/cardiovascular.rs). Every unit the units file accepts has at least one vector. tests/calculators.rs checks every vector to 2 decimals, and a control proves that one wrong expected value fails the suite.