Skip to content

Ingestion and normalization

How a document or a structured file becomes observations with provenance. This covers lab PDFs, scans and photos, structured imports, and the non-lab documents we store but do not yet extract.

The pipeline has no chat agent and no built-in LLM. It is a fixed chain of jobs. Only the extractor step is pluggable, and every extractor returns the same shape: candidate rows with per-field confidence and a bounding box. Nothing is dropped silently: a row that fails a check goes to the review queue, where a person sees it next to the page crop it came from.

1. What ships when

Piece Phase
Upload in the UI, manual entry v0.1
PDF text layer (pdfplumber, pypdfium2) v0.1
Vendor templates + generic table rules v0.1
LOINC/UCUM normalization, flags from the lab's own range v0.1
Review queue v0.1
FHIR R4 / IPS bundle import, Apple Health export zip (incl. clinical-records/) v0.1
Store + full-text index for non-lab documents, listed in the document vault v0.1
Watched folder, email-in, Paperless-ngx webhook, PWA share target, iOS Shortcut v0.2
ocr compose profile (scans and photos) v0.2
Agent-assisted extraction (list_pending_documents, get_document_page, propose) v0.2
Non-lab documents on the timeline v0.3
C-CDA import v1.0
HL7 v2 ORU^R01 and lab CSV importers v2
Extraction from discharge letters, imaging reports, prescriptions after v0.3
Optional cited "optimal" ranges not scheduled, off by default, see Open decisions

2. Pipeline

flowchart TD
  subgraph IN[Inboxes]
    I1[Upload UI / PWA share target / iOS Shortcut]
    I2[Watched folder]
    I3[IMAP: allowlist, per-sender PDF password]
    I4[Paperless-ngx: Document Added webhook + API pull]
    I5[Manual entry]
    I6[Structured: FHIR R4, IPS, Apple Health zip; C-CDA v1.0; HL7v2, CSV v2]
  end
  I1 & I2 & I3 & I4 --> B[Blob store: sha256, immutable]
  I3 -->|sender not allowlisted| QZ[Quarantine: stored, not processed]
  B --> D{Dedup: exact hash, then page pHash + text simhash}
  D -->|duplicate| DL[Link as extra source, stop]
  D -->|new| C[Classify: doc type, language, provider fingerprint, patient block, dates]
  C -->|non-lab| FT[Store + full-text index]
  C -->|lab| T{Text layer usable on this page?}
  T -->|yes| TL[pdfplumber / pypdfium2: words + bbox + font]
  T -->|no| OCR[ocr profile: PP-StructureV3 / Docling CPU, PaddleOCR-VL GPU]
  T -->|no and ocr profile off| PEND[Pending: waits for OCR or agent]
  TL & OCR --> PM[Page model: words, lines, tables, reading order]
  PM --> X1[1. Vendor template]
  X1 -->|no match or too few rows| X2[2. Generic table rules]
  X2 -->|too few rows| PEND
  PEND --> X3[3. Agent-assisted: outside agent calls propose over MCP]
  X1 & X2 --> CR[CandidateRows: per-field confidence + bbox]
  X3 --> CR
  I6 --> NZ
  I5 --> NZ
  CR --> NZ[Normalize: LOINC from name + unit + specimen, UCUM, value parse, ranges, flags]
  NZ --> V{Validate: LOINC exists, unit dimension vs LOINC property, plausibility, grounding, identity, dates}
  V -->|auto-accept rule holds, section 9| OK[(Observation: current, accepted_by auto)]
  V -->|anything else| RQ[Review queue: crop + row + reasons]
  RQ -->|accept / edit| OBS[(Observation: current, accepted_by person)]
  RQ -->|reject| RJ[Review item rejected, no observation]
  OK & OBS --> TR[Truth layer: printed_* + derived layer: LOINC, UCUM, canonical value, flag]

Each step is a row in the Postgres job table, picked with SELECT ... FOR UPDATE SKIP LOCKED by the in-process job loop. Every step writes its output plus the tool name and version, so "why does this say 140?" always resolves to: blob, page 2, bbox, engine pdfplumber 0.11.x, extractor template:examplelab-es-v3, resolver alias:ldl-es-04.

3. Inboxes

All inboxes produce the same thing: a blob, a document row with source_channel and source_ref, and a profile hint. The profile hint is never trusted alone (see the Identity check in section 9).

Inbox Mechanism Profile hint Phase
Upload UI Drag and drop, multi-file, POST /api/ingest/upload Profile picked in the UI v0.1
Manual entry Form with name autocomplete from the alias table, unit picker filtered by the resolved LOINC property The profile being edited v0.1
Watched folder Polling (inotify is unreliable on SMB/NFS mounts) of /inbox/<profile-slug>/. A file is taken once its size is unchanged for 10 s. After the blob commits it moves to /inbox/.done/, on failure to /inbox/.failed/ with a .reason.txt Subfolder name v0.2
Email-in (IMAP) Dedicated mailbox, polled every 60 s (no IDLE: the poll alone meets the 2-minute target). Attachments become documents (application/octet-stream too, sniffed by content; inline cid: images are skipped). The HTML/text body is not a document: it stays inside the stored .eml and nothing parses it. Processed mail moves to an OwnHealth/Done folder. Implicit TLS or STARTTLS; no TLS only to a loopback or private address; ca_file for a home server's own CA Sender rule v0.2
Paperless-ngx Webhook + API pull, polling fallback (3.1) Tag or correspondent rule v0.2
PWA share target share_target in the web manifest, POST multipart/form-data to /api/ingest/share. Android only, iOS Safari has no share target Profile chosen on the share screen v0.2
iOS Shortcut A published Shortcut that POSTs the shared file to /api/ingest/upload with an upload-only token Token is bound to one profile v0.2
Structured imports FHIR R4 Bundle, IPS / EU Patient Summary (FHIR), Apple Health export zip. C-CDA in v1.0; HL7 v2 ORU^R01 and lab CSV in v2 Patient resource matched to a profile, else asked v0.1 (FHIR, IPS, Apple), v1.0 (C-CDA), v2 (HL7 v2, CSV)

3.1 Paperless-ngx

  1. The user creates a Paperless workflow: trigger "Document Added", filter tag health, action Webhook to https://<ownhealth>/api/ingest/paperless with body {"doc_url": "{{doc_url}}"} and a header X-OwnHealth-Secret. Paperless needs PAPERLESS_URL set or doc_url is null.
  2. We parse the document id from doc_url and pull the original through GET /api/documents/<id>/download/?original=true with a Paperless API token (read-only user recommended). We never trust document content in the webhook body.
  3. If the original has no usable text layer, we also pull the archived PDF (/download/ without original), which carries Paperless's OCRmyPDF/Tesseract layer. We treat that layer as OCR output (engine: paperless-tesseract, OCR-level confidence), never as a native text layer.
  4. We write back the tag ownhealth-imported and store the Paperless id as source_ref. Custom fields in webhook templates are recent (PR 14559), so we do not depend on them.
  5. Polling fallback: GET /api/documents/?tags__id__in=<health>&modified__gt=<cursor> every 15 min, for setups where Paperless cannot reach us.

https://docs.paperless-ngx.com/usage/ https://docs.paperless-ngx.com/api/ https://github.com/paperless-ngx/paperless-ngx/pull/14559

3.2 Email-in

  • Allowlist only. A sender rule is {address or domain, profile, doc_type_hint, pdf_password_ref}. We match on the From address and require Authentication-Results to show DKIM or SPF pass for that domain, because From alone is trivial to forge. A pass proves the domain, not the mailbox. An address rule therefore relies on the sender's mail service letting each account send only as its own address, which the large providers enforce. Where a domain's server lets one account send as another address, the rule in effect trusts the whole domain, and the setup guide (docs/recipes/email.md) says so. Only a header stamped by the receiving server counts: the inbox setting trusted_authserv_id names it, and any Authentication-Results with another authserv-id is ignored, because a sender can write that header too. The setup guide asks the user to confirm their mail server strips incoming headers that claim its own authserv-id (RFC 8601 section 5); most do. If the receiving server adds no Authentication-Results, the rule must say trust_unauthenticated: true explicitly.
  • Quarantine. Mail from anyone else is stored as a blob with status: quarantined and is not classified, extracted or indexed. The UI shows the quarantine list with sender, subject and attachment names. Actions: release once, release and add sender, delete.
  • Per-sender PDF passwords. Many Spanish portals mail PDFs encrypted with a password derived from the patient's ID document number. The password lives in the secrets table, encrypted at rest, referenced by id from the sender rule. We try only that sender's passwords, never a global list. Passwords never appear in logs, job payloads, audit rows or error messages. A PDF that will not open goes to review as encrypted_unknown_password.
  • We store the decrypted PDF as a second blob linked to the encrypted original (derived_from), so the original bytes stay intact.
  • Limits: 25 MB per attachment, 50 attachments per message, MIME types application/pdf, image/*, application/zip (structured exports), application/fhir+json, application/json, text/xml. Anything else is stored and listed, not processed.
  • Dedup on Message-ID in addition to blob hash.

3.3 Structured imports

Structured inputs skip OCR and extraction. They go straight to normalization and validation, with provenance pointing at the resource instead of a bbox: {blob, resource_type, resource_id, json_pointer}, for example Bundle.entry[14].resource.valueQuantity.

  • FHIR Observations with a LOINC code and a valid UCUM valueQuantity can auto-accept. Missing code, unknown code or unit that will not parse goes to review like any other row.
  • Observation.note, DiagnosticReport.conclusion and any narrative (text.div) are stored as untrusted text (section 10).
  • An IPS or EU Patient Summary often arrives as a PDF only. We treat it as a document, and also check for embedded files (PDF attachments, XMP) carrying the FHIR or CDA payload.
  • The Apple Health zip: clinical-records/*.json are FHIR resources and follow this path. The export.xml samples belong to the wearables path and are out of scope here.

4. Blob store and dedup

  • Bytes go to blobs/sha256/ab/cd/<full-hash> before any processing. Blobs are immutable. Re-processing creates a new extraction_run, never a new blob.
  • Dedup levels:
  • Exact: same sha256 for the same profile. The new arrival becomes an extra document_source row (channel, ref, received_at) on the existing document. Processing stops.
  • Near-duplicate: per-page perceptual hash of the rasterized page (Hamming distance <= 6 on a 64-bit pHash) plus a simhash of normalized text (Hamming distance <= 4). Every page needs its simhash: two reports from the same lab template are 0 to 2 pHash bits apart whatever values they hold, so the pHash alone never decides, and a scan is compared once OCR has read its words. Catches a portal re-download with a new footer timestamp, or a scan of a printout we already hold. A near-duplicate is processed, then shown in review as "probably the same as document X" with a link-instead-of-import action.
  • Observation level: same profile + alias_group + equal canonical value + same comparator + same method (direct or calculated) + same collection time, from two sources = one logical fact with two provenance links. Trends count it once. A missing collection time on either side, or a different comparator, sends the row to review instead (architecture.md section 10). A row that matches nothing still runs the Conflict check of section 9: the same analyte on the same day with a different value goes to review as conflict. The same value from another lab, or at another time of day, is kept as its own fact.

5. Classification

Rule-based in v0.1, user-overridable in the UI. No model.

Output How
doc_type: lab, imaging_report, discharge_letter, prescription, genomics_report, patient_summary, other Keyword sets per language on the first two pages ("Hemograma", "Bioquímica", "Informe de alta", "Befund", "Compte rendu", "Laboratory report") plus provider fingerprint
language Character n-gram detector over the text layer; es, en, de, fr first
Provider fingerprint Header words, logo image hash, column header words; selects a vendor template
Patient block Name, date of birth, sex, lab sample id (hashed) from the page header
Dates Collection date ("Fecha de extracción", "Entnahme", "Date de prélèvement", "Collected"), report date, validation date
Report status "Informe provisional", "vorläufiger Befund", "preliminary", "amended", "rectificado"

6. Text layer first, OCR second

Most lab PDFs from hospital groups and large labs are born digital. Their text layer is exact and costs nothing to read. We test every page, because scanned annex pages inside digital reports are common.

A page's text layer is usable when all hold: - at least 150 characters on the page; - at least 50% of tokens of 3+ letters are found in the es/en/de/fr word lists; - no (cid:NN) glyph runs, and fewer than 5% of characters in the Private Use Area (fonts without a ToUnicode map).

Library Licence Use
pdfplumber (pdfminer.six) MIT Words with bbox, font name, size and fill colour; table heuristics. Default reader.
pypdfium2 Apache-2.0 / BSD-3 Page rasterization for OCR, crops for the review UI, fast char boxes (detail of the word-bbox API unverified)
PyMuPDF AGPL-3.0 Licence-compatible with our AGPL, but not used: we chose pdfplumber + pypdfium2 (PLAN.md)

Font colour, size and position are kept per word, because the injection checks in section 10 need them.

6.1 OCR engines

Only scans, photos and pages that fail the usable check reach OCR. OCR runs only in the ocr compose profile. Without it, those pages wait as pending for OCR or for agent-assisted extraction. Every engine sits behind one interface:

def ocr_page(image: bytes, lang_hint: list[str]) -> PageModel:
    # words[], lines[], tables[], reading_order, engine, engine_version

Photos get orientation fix, deskew and dewarp first (PaddleOCR ships document orientation and unwarping modules).

Engine Code / weights licence Hardware Tables Notes Our use
PaddleOCR 3.x PP-StructureV3 Apache-2.0 CPU Yes, to HTML/JSON 100+ languages; no Intel iGPU path verified Default CPU engine (candidate, with Docling)
Docling MIT code; models Apache-2.0 / CDLA-Permissive-2.0 / MIT CPU, a few s/page TableFormer, good on clean tables Cleanest licence stack; does text-first then OCR (EasyOCR, Tesseract or RapidOCR) Default CPU engine (candidate, with PP-StructureV3)
PaddleOCR-VL 0.9B Apache-2.0 repo; weights Apache-2.0 (Hugging Face model card) Small GPU or iGPU; slow on CPU Strong (vendor OmniDocBench claim, unverified) 109 languages Candidate GPU/iGPU default, pending eval numbers
Tesseract 5 Apache-2.0 CPU No spa/deu/fra data; weak on phone photos Fallback only
docTR Apache-2.0 CPU, GPU optional No Good word boxes Plug-in
MinerU 3.x From 3.1.0 Apache-2.0 plus extra conditions; up to 3.0.9 AGPL GPU Very strong Read the extra terms first Opt-in plug-in, not default
Marker / Surya Code Apache-2.0 or GPL; weights modified OpenRAIL-M with a revenue cap GPU Good Not safe as a default for others to rehost Opt-in plug-in
olmOCR 2 Apache-2.0 7B, needs 12-16 GB VRAM Good Training data mostly English Opt-in plug-in
DeepSeek-OCR 2, dots.ocr Apache-2.0; MIT plus extra agreement GPU, ~3B Good Check dots terms Opt-in plug-in

Throughput on an Intel integrated GPU (OpenVINO, llama.cpp SYCL) is unmeasured. We publish numbers from the eval harness (section 13) before we recommend a GPU default for that hardware. Target for the default profile: the app container plus ocr on CPU in 4 GB RAM.

The things that break lab tables are layout, not characters: wrapped analyte names, the range column read as the value (3,5 - 5,0 next to 4,1), decimal commas, thousands separators (250.000/µL in Spanish is 250000), flags carried as bold or arrows, non-numeric results (<0,5, negativo, indetectable, trazas), and repeated header blocks on every page. Sections 7 and 8 target these.

https://github.com/PaddlePaddle/PaddleOCR https://huggingface.co/PaddlePaddle/PaddleOCR-VL https://github.com/docling-project/docling https://opendatalab.github.io/MinerU/reference/changelog/ https://huggingface.co/datalab-to/surya-ocr-2/blob/main/LICENSE https://allenai.org/blog/olmocr-2 https://github.com/studio-dots-ai/dots.ocr

7. Extractor chain

class Extractor(Protocol):
    id: str          # "template:examplelab-es-v3", "rules:generic-table-v1", "agent:propose"
    version: str
    def applies(self, doc: DocMeta, pages: list[PageModel]) -> float: ...   # 0..1
    def extract(self, doc: DocMeta, pages: list[PageModel]) -> list[CandidateRow]: ...
Order Extractor Runs when Auto-accept allowed
1 Vendor template (YAML: fingerprint, anchors, column x-ranges, row regex, value locale) Fingerprint score >= 0.8 Yes
2 Generic table rules (find a block with name / value / unit / range columns, group rows by y-overlap and font) No template, or the template returned < 50% of the rows the page appears to hold Yes, text layer only
3 Agent-assisted (outside agent over MCP) The page is pending and an agent with write:propose works on it Never

Rules for the chain: - There is no model inside the chain. A page that steps 1 and 2 cannot read waits as pending for an outside agent (7.2) or for manual entry. - When two extractors read the same row and agree on (alias_group, value, unit), confidence rises by 0.1 (cap 0.99). When they disagree, the row goes to review with both readings. - Template learning: after a person corrects rows from an unknown layout, the UI offers "save as template for this provider". It records anchors and column x-ranges only, no values and no patient block. Templates live in the repo as YAML under src/ownhealth/ingest/pdf/vendors/<country>/<provider>.yaml (architecture.md section 5), reviewed like code.

7.1 CandidateRow

{
  "document_id": "doc_01J9...",
  "page": 2,
  "bbox": [56.2, 410.8, 538.0, 423.1],
  "extractor": "template:examplelab-es-v3",
  "extractor_version": "3.1.0",
  "engine": "pdfplumber 0.11",
  "cells": {
    "name":      {"text": "Colesterol LDL",   "bbox": [56.2, 410.8, 160.4, 423.1], "conf": 0.99},
    "value":     {"text": "131",              "bbox": [300.1, 410.8, 318.6, 423.1], "conf": 0.99},
    "unit":      {"text": "mg/dL",            "bbox": [340.0, 410.8, 372.5, 423.1], "conf": 0.99},
    "ref_range": {"text": "< 116",            "bbox": [420.0, 410.8, 452.2, 423.1], "conf": 0.98},
    "flag":      {"text": "*",                "bbox": [322.0, 410.8, 327.0, 423.1], "conf": 0.95},
    "method":    {"text": "Calculado (Friedewald)", "bbox": null, "conf": 0.90}
  },
  "row_conf": 0.95
}

Bboxes are PDF points, origin top-left, in the page's own coordinate space. row_conf = min over required cells (name, value, unit) times the extractor prior (template 1.0, rules 0.95, OCR-backed rows times the mean OCR word confidence).

7.2 Agent-assisted extraction (v0.2)

The outside agent does the reading the app cannot do, and OwnHealth checks every digit.

sequenceDiagram
  participant A as Outside agent
  participant M as OwnHealth MCP
  participant P as Pipeline
  participant H as Person (UI)
  A->>M: list_pending_documents(profile)
  M-->>A: ids, doc_type, page count, why pending
  A->>M: get_document_page(doc, page)  [needs read:documents_text]
  M-->>A: page image + word layer, trust: untrusted_text
  A->>M: propose(profile, "observations", rows)  [needs write:propose]
  M->>P: normalize + validate + ground each row
  P-->>M: per-row result: queued / rejected with reason
  M-->>A: summary, review queue link
  H->>P: accept / edit / reject in review queue

propose payload for kind observations:

{
  "document_id": "doc_01J9...",
  "rows": [
    {"page": 1, "printed_name": "TSH", "printed_value": "2,41", "printed_unit": "µUI/mL",
     "printed_ref_range": "0,35 - 4,94", "bbox": [60, 300, 520, 312]}
  ],
  "note": "Rows from page 1 table 'Hormonas'"
}

bbox is optional. Grounding runs on every row either way. A page with no word layer (a scan while the ocr profile is off) gives grounding nothing to check against; its agent rows go to the review queue marked ungrounded_no_word_layer, shown next to the page image so the person compares each digit, and they never count as grounded. Such a row is stored as a candidate row like any other; when the agent sent no bbox, its bbox is null and the review shows the whole page. A row whose value is not on the page is returned as rejected: not_grounded and also stored in the review queue as rejected, so the person sees what the agent claimed. Proposals never auto-accept. The review item records the agent's token id and, from the audit log, which documents and src ids that token read in the hour before the proposal (security-privacy.md).

8. Normalization

8.1 Value parsing

  • Locale per document (from language and template). In es/de/fr, , is decimal and . groups thousands; in en the reverse. A value with both is parsed by the last separator. A lone . followed by exactly 3 digits in an es/de/fr document is a thousands separator only when the unit is a count (/µL, /mm3, x10^3/µL); otherwise the row goes to review as ambiguous_separator.
  • Comparators: <, >, <=, >=, ≤, ≥, inferior a, kleiner als go to value_cmp.
  • Text results: negativo, positivo, indetectable, no detectado, trazas, negativ, nicht nachweisbar, négatif, absence map to a small coded set (negative, positive, not_detected, trace) with the printed text kept.
  • Unicode clean-up for matching only: µ/μ/u, –/-/−, non-breaking spaces. The printed string is stored as found.

8.2 LOINC resolution

v0.1 ships our own curated LOINC 2.83 subset (202 codes, checked on tx.fhir.org) under the LOINC License, and our own multilingual alias tables. Mirobody's resolver overlays are not imported. LOINC ships with its notice and version number. Codes are optional enrichment: an uncoded row stays usable under its alias_group.

Resolution order: 1. Normalize the printed name: lowercase, strip accents (matching only), drop specimen prefixes (S-, P-, Suero, Sangre, Serum), expand per-language abbreviations. 2. Look up our alias table with (name, language, unit dimension, specimen hint, method hint). The unit dimension picks the code: LDL in mg/dL is a mass concentration code, in mmol/L a substance concentration code. 3. Fall back to the LOINC linguistic variants (es-ES, de-DE, fr-FR), which are formal names and rarely match what labs print. 4. Panel and category names ("Perfil lipídico", "Hemograma completo", "Blutbild") are refused, never coded as an analyte. 5. No match: loinc = null, alias_group = normalized printed name scoped to the provider, and a review item unmapped. We never create a second series for an analyte that already has one: when the alias table grows, ownhealth rederive re-links history and recomputes the derived layer.

Calculated and measured values keep separate codes and a visible marker in trends (Friedewald vs direct LDL; eGFR CKD-EPI 2009 vs 2021).

Sample rows of data/terminology/aliases/{es,en,de,fr}.tsv (codes marked † still to be checked against the LOINC release we ship):

alias (as printed) lang specimen property method LOINC
Colesterol LDL / c-LDL es Ser/Plas MCnc calculated 13457-7
Colesterol LDL directo es Ser/Plas MCnc direct 18262-6
LDL Cholesterol / LDL-C en Ser/Plas MCnc calculated 13457-7
LDL-Cholesterin de Ser/Plas MCnc any 2089-1
LDL-Cholesterin de Ser/Plas SCnc calculated 39469-2
Cholestérol LDL / LDL-cholestérol fr Ser/Plas SCnc calculated 39469-2
Hemoglobina glicada (HbA1c) es Bld MFr (%) any (%, DCCT/NGSP units) 4548-4
Hemoglobina glicosilada A1c es Bld SFr (mmol/mol) IFCC 59261-8
Hemoglobin A1c en Bld MFr (%) any (%, DCCT/NGSP units) 4548-4
HbA1c / Glykiertes Hämoglobin de Bld SFr (mmol/mol) IFCC 59261-8
Hémoglobine glyquée fr Bld MFr (%) any (%, DCCT/NGSP units) 4548-4
TSH / Tirotropina es Ser/Plas ACnc any 3016-3
TSH / Thyroid stimulating hormone en Ser/Plas ACnc any 3016-3
TSH basal / Thyreotropin de Ser/Plas ACnc any 3016-3
TSH / Thyréostimuline fr Ser/Plas ACnc any 3016-3
Ferritina es Ser/Plas MCnc any 2276-4
Ferritin en / de Ser/Plas MCnc any 2276-4
Ferritine fr Ser/Plas MCnc any 2276-4
25-OH Vitamina D / Calcidiol es Ser/Plas MCnc D2+D3 62292-8 †
25-Hydroxy Vitamin D en Ser/Plas MCnc D2+D3 62292-8 †
25-OH-Vitamin D3 de Ser/Plas MCnc D3 only 1989-3 †
Vitamine D (25-OH) fr Ser/Plas SCnc D2+D3 † (code to pick)
Creatinina es Ser/Plas MCnc any 2160-0
Creatinine en Ser/Plas SCnc any 14682-9
Kreatinin de Ser/Plas MCnc any 2160-0
Créatinine fr Ser/Plas SCnc any 14682-9
Filtrado glomerular estimado (CKD-EPI) / FGe es Ser/Plas ArVRat CKD-EPI 2021 98979-8
eGFR (CKD-EPI 2021) en Ser/Plas ArVRat CKD-EPI 2021 98979-8
eGFR (CKD-EPI) / GFR geschätzt de Ser/Plas ArVRat CKD-EPI, year unstated 62238-1 †
DFG estimé (CKD-EPI) / DFGe fr Ser/Plas ArVRat CKD-EPI, year unstated 62238-1 †

Each alias row carries source (curated, mirobody, loinc-variant) and a review date. An eGFR row whose formula year is not printed is coded as the older CKD-EPI code and marked method_uncertain; we never assume 2021.

https://loinc.org/kb/license https://loinc.org/international/spanish/ https://github.com/thetahealth/mirobody https://github.com/thetahealth/mirobody/issues/234 https://github.com/thetahealth/mirobody/blob/main/LICENSE-3RD-PARTY https://loinc.org/4548-4

8.3 Units and UCUM

  • Store the unit exactly as printed, the parsed UCUM code, and a canonical value in one canonical unit per alias_group. Conversion is derived and never destructive.
  • Printed-unit synonyms map to UCUM: mg/dl, mg% to mg/dL; x10^3/µL, 10^9/L, x10E3/uL, miles/µL to 10*3/uL or 10*9/L; /mm3 and /µL to /uL (a count per microlitre, so converting to 10*3/uL divides the value by 1,000); UI/L, IE/l to [IU]/L; U/l to U/L; mUI/mL, µUI/mL, µIU/mL to m[IU]/mL or u[IU]/mL. [IU] and U are not interchangeable.
  • Unit dimension vs LOINC property: the parsed unit's dimension must match the resolved code's property (MCnc = mass/volume, SCnc = substance/volume, ACnc = arbitrary units/volume, CCnc = catalytic/volume, NCnc = count/volume, MFr/SFr = fraction, ArVRat = volume rate/area). A mismatch sends the row to review. This one check catches most column shifts.
  • Mass to molar needs a molar mass per analyte. UCUM cannot infer it and wrong molar masses are a documented failure. We keep normalize/terminology/molar/molar_mass.tsv, one row per analyte, with a citation and a unit test per entry:
alias_group Species used g/mol Conventional to SI Trap
glucose glucose 180.16 mg/dL x 0.05551 = mmol/L
cholesterol (total, LDL, HDL) cholesterol 386.65 mg/dL x 0.02586 = mmol/L
triglycerides triolein (lab convention) 885.4 mg/dL x 0.01129 = mmol/L Not a single molecule; convention only
creatinine creatinine 113.12 mg/dL x 88.40 = µmol/L
urea urea 60.06 mg/dL x 0.1665 = mmol/L
BUN urea nitrogen (2 N) 28.01 mg/dL x 0.357 = mmol/L urea Urea and BUN differ by x2.14
uric acid uric acid 168.11 mg/dL x 59.48 = µmol/L
bilirubin bilirubin 584.66 mg/dL x 17.10 = µmol/L
calcium Ca 40.08 mg/dL x 0.2495 = mmol/L
phosphate P (as phosphorus) 30.97 mg/dL x 0.3229 = mmol/L Not PO4 (94.97)
magnesium Mg 24.31 mg/dL x 0.4114 = mmol/L
iron Fe 55.85 µg/dL x 0.1791 = µmol/L
25-OH vitamin D calcidiol (D3) 400.64 ng/mL x 2.496 = nmol/L
vitamin B12 cyanocobalamin 1355.37 pg/mL x 0.7378 = pmol/L
folate folic acid 441.40 ng/mL x 2.266 = nmol/L
testosterone testosterone 288.42 ng/dL x 0.03467 = nmol/L
cortisol cortisol 362.46 µg/dL x 27.59 = nmol/L

Conversions that are not molar live in the same file with a kind field: - HbA1c: IFCC mmol/mol = 10.929 x (NGSP % - 2.15), the NGSP/IFCC master equation. https://ngsp.org/ifccngsp.asp - Identity: ferritin ng/mL = µg/L; TSH µUI/mL = mUI/L. - eGFR: mL/s/1.73 m² x 60 = mL/min/1.73 m².

A unit we cannot convert is never stored silently next to convertible ones: the row keeps its printed value, gets unit_canonical = null, and a review item unit_unconvertible appears.

https://ucum.org https://ucum.nlm.nih.gov/ucum-service.html https://github.com/dalito/ucumvert https://pubchem.ncbi.nlm.nih.gov/

8.4 Reference ranges

  • The range as printed is stored per observation: low, high, text, and applicability text ("Mujeres: 12-16", "Männer", "Hommes", "3er trimestre"). Ranges are per lab, method, age, sex and pregnancy stage, so we never replace a printed range with a global one.
  • Conditioned ranges parse into ref_ranges[] with applies_to {sex, age_min, age_max, pregnancy}. We pick the applicable one from the profile's sex and age at effective_at. If none applies or the parse is ambiguous, the row goes to review.
  • No printed range means no flag. The status rule pack sees range: none.
  • Optional cited "optimal" ranges (not scheduled): a YAML pack, off by default, each entry with a citation URL, population and date. Shown as a second, labelled band on charts. Never used for flags or status.

8.5 Interpretation flags

  • printed_flag keeps what the lab printed (H, L, *, ↑, ↓, bold), read from the text or the font weight.
  • interpretation is computed from the applicable printed range only: L, N, H, or A for abnormal text results, as HL7 ObservationInterpretation codes. Critical (LL, HH) only when the lab prints it.
  • When the printed flag and the computed one disagree, the row goes to review as flag_mismatch. This is a strong sign of a mis-parsed range or a column shift.

9. Validation and acceptance

Every candidate row, from any source, runs the same validators. Each failure adds a reason code to the review item.

Check Rule Reason code
LOINC exists Code is in the shipped LOINC cut and not deprecated loinc_unknown, loinc_deprecated
Unit dimension UCUM dimension matches LOINC property unit_dimension_mismatch
Converts Canonical value computable unit_unconvertible
Plausibility Within hard physiological limits per alias_group (data/terminology/limits/labs.tsv, e.g. glucose 10-1000 mg/dL, sodium 90-200 mmol/L, HbA1c 3-20 %) implausible
Factor 1000 Value out of limits but value x1000 or /1000 is inside suspect_separator
Range sanity low < high; the value cell does not itself look like a range (70 - 110). A value on a bound is real (HbA1c 5.6 with 4.0 - 5.6) and passes range_parse, value_is_range
Grounding Value token (separator-tolerant) found in the page word layer, inside the row bbox +/- 4 pt for rule extractors, anywhere on the page for agent rows; name tokens on the same line band. For a structured import (FHIR, Apple Health) the value must be the one at the row's json_pointer or record in the stored blob not_grounded, name_not_on_line
Identity Patient name and birth date on the page match the target profile (fuzzy, accent-insensitive). For a structured import, the resource's linked Patient (name, birth date, identifiers) matches the profile; an Apple Health export is bound to the profile chosen at upload identity_mismatch, identity_missing
Dates Collection date not in the future, not before birth, not after report date date_invalid
Duplicate Same fact already accepted from another source duplicate (link, not import)
Conflict Same alias_group + date, different value, already accepted conflict

9.1 Auto-accept rule

A row is committed without a click only when all of these hold: - every check in the table above passes; - row_conf >= 0.95 (instance setting ingest.auto_accept_threshold, never below 0.90); - the source allows it: a known vendor template or generic rules on a native text layer; OCR with a matching vendor template at row_conf >= 0.98; or a structured import with a valid code and unit; - identity is matched, not just hinted: the Identity check passed on the page itself (or on the linked Patient for a structured import), not only the inbox's profile hint.

An auto-accepted row is labelled accepted_by: auto and stays one click away from correction in the UI. Agent proposals and any row with a reason code always go to review. A document whose rows all passed the checks but missed the threshold can be bulk-accepted in the UI with one action; those rows are labelled accepted_by: person.

The eval gate in section 13 holds the rule honest: a false auto-accept on the eval set blocks the merge.

9.2 States

Review items are open, accepted, rejected or dismissed. A rejected row never becomes an observation; the review item keeps what was read, so the person can reopen it.

Observations follow the fact lifecycle used across OwnHealth: provisional, current, superseded, retracted.

stateDiagram-v2
  [*] --> candidate
  candidate --> current: auto-accept rule holds (accepted_by auto)
  candidate --> provisional: auto-accept rule holds, report marked preliminary
  candidate --> open: any reason code, or agent proposal
  open --> current: accept or edit (accepted_by person)
  open --> provisional: accept, report marked preliminary
  open --> rejected: reject
  rejected --> open: reopen
  provisional --> current: final report confirms the value
  provisional --> superseded: final report changes the value
  current --> superseded: correction or amended report
  current --> retracted: entered in error, with reason

open and rejected are review item states; provisional, current, superseded and retracted are observation states.

10. Imported text is untrusted

Lab PDFs, email bodies, Paperless documents, FHIR narratives and agent notes can carry text written to steer an agent ("ignore previous instructions and..."). The pipeline itself has no LLM to steer, so the risk is what an outside agent reads later. What we do at ingest:

  1. Structured over text. Extraction stores cells. Free text that we keep (comments, narrative, the full-text index) is tagged trust: untrusted_text and is returned over MCP only inside that marker. Raw page text and page words sit behind get_document_page / get_source with scope read:documents_text, off by default.
  2. Hidden text detection per page, stored as page flags and shown in review:
  3. fill colour within 5% luminance of the background behind it (white on white);
  4. font size under 2 pt;
  5. words outside the CropBox or under an opaque image;
  6. text-layer words with no matching OCR word on the rendered image (only when the ocr profile runs);
  7. text in PDF metadata, XMP, annotations, form fields and embedded files (stored, never extracted as values).
  8. Instruction-pattern flag. A small multilingual pattern list ("ignore previous", "system prompt", "you are now", "call the tool", URLs inside lab tables) raises a visible possible_injection warning on the document. It is a warning, not a filter: we keep the text, because silently dropping content breaks principle 2.
  9. No outbound path. No ingest step and no MCP tool can send data out (no share, no export, no email). The pipeline calls no model endpoint.
  10. Writes go through review. Every propose lands in the queue with the list of documents the token read beforehand.
  11. Fixtures. tests/fixtures/injection/ holds synthetic PDFs for each case above plus a FHIR Observation.note and an email body. CI asserts each one is flagged, that no value is extracted from hidden text, and that the text comes back over MCP only with trust: untrusted_text.

11. Corrections, versioning, amended reports

  • Truth layer vs derived layer. printed_name, printed_value, printed_unit, printed_ref_range, printed_flag, page and bbox never change. LOINC, UCUM, canonical value, applicable range and interpretation are derived and carry a derivation_version (normalizer code, alias table, resolver and conversion table versions). A new derivation version recomputes the derived layer in a job, which supersedes each row it changes with a copy holding the same truth layer (architecture.md section 13); the status state_hash changes with it.
  • Correction by a person: a new observation with supersedes = old.id; the old one becomes superseded. A value entered in error becomes retracted with a reason. Nothing is deleted. The reviewer and an optional note are stored.
  • Amended or final report: the lab sends a new edition. The earlier document gets superseded_by pointing at the new one when provider + collection date + hashed sample id match, or >= 50% of alias_groups overlap on the same collection date. Identical rows are linked, new rows added, changed values go to review as amended_value with both shown. A preliminary report's rows are provisional until the final arrives.
  • Ordered but missing: a "pendiente", "folgt", "à suivre" or "pending" line becomes an expected_test row on the report, so "what is still pending?" has an answer.
  • Re-extraction after a template or engine upgrade: a new extraction_run, diffed against accepted rows. Only differences go to review. An accepted value is never overwritten.
  • Delete is soft with a reason. Hard purge of a document and its blob is a separate explicit action, logged in the audit table, as in architecture.md section 7.

11.1 Tables

The DDL lives in one place: architecture.md section 6.2. This pipeline needs these tables and columns from it:

  • document with blob hash, channel and ref, doc_type, language, provider fingerprint, report status, collection and report dates, superseded_by, flags.
  • document_source: one row per arrival of the same blob (channel, ref, received_at), for exact-duplicate links (section 4).
  • document_page with text_layer_ok, the word layer, a perceptual hash, hidden-text flags and a tsvector for full-text search.
  • extraction_run and candidate_row (section 7.1).
  • observation with the truth layer (printed_*, page, bbox), the derived layer and derivation_version, accepted_by, supersedes, lifecycle status.
  • review_item whose kind comes from architecture's list; the fine reason codes from section 9 go in its payload, with context_src_ids from the audit log.
  • expected_test(report_document_id, printed_name, reason) for ordered tests not yet reported.

observation.fhir is the FHIR-shaped Observation; the typed columns are projections for queries.

12. Non-lab documents

Discharge letters, imaging reports, prescriptions, referral letters and patient summaries in PDF form: - v0.1: stored, classified, text layer read (OCR when the profile is on), full-text indexed with Postgres tsvector using the document's language configuration (spanish, english, german, french, simple as fallback). Listed in the document vault by date and type, and searchable in the UI. They join the timeline in v0.3. Over MCP the text is reachable only through read:documents_text and marked untrusted. - Later: extraction of diagnoses, medications and procedures. Codes stay optional: SNOMED CT is bring-your-own (never shipped), ATC is stored per product only, never as a shipped table. An agent can already propose medications and notes from these documents through propose in v0.2.

13. Evaluation

No public benchmark covers multilingual lab reports, so we build one, fully synthetic.

  • Generator: tools/labslips/ renders lab slips from HTML templates to PDF. Synthetic people only (Alex Rivera, Sam Rivera, Lucía Rivera, Carmen Ortega). Each slip comes with ground-truth JSON: every row's name, value, unit, range, flag, page and bbox.
  • Coverage: es, en, de, fr; at least 6 layouts per language (single column, two column, wrapped names, flags as arrows, flags as bold, multi-page with repeated header); decimal comma and thousands-separator cases; non-numeric results; sex-conditioned ranges; one amended report pair per language.
  • Variants: born-digital PDF; rasterized at 200 dpi; phone-photo simulation (perspective, blur, JPEG 60, uneven light); a PDF with a broken ToUnicode map.
  • Injection set: section 10 fixtures.
Metric Definition Gate
False auto-accept rate Auto-accepted rows whose value, unit or code differ from truth 0 on the whole set, blocks merge
Row recall Truth rows that reach the queue or the record >= 0.98 born-digital, >= 0.90 photos (target)
Value exact match After normalization, among extracted rows >= 0.995 born-digital (target)
Unit match UCUM code equal to truth >= 0.99 (target)
LOINC top-1 On analytes the alias table covers >= 0.97 (target)
Review rate Share of rows needing a person Tracked per extractor and engine, no gate
Grounding catches Planted wrong values in agent proposal fixtures rejected 100%, blocks merge
Injection flags Fixtures flagged and not extracted 100%, blocks merge
Throughput Pages/min per engine and hardware Published, no gate

The eval runs in CI on the born-digital set for every change to templates, rules, aliases or units. OCR engine runs happen on a schedule on a self-hosted runner with the ocr profile, and the numbers go into docs/benchmarks/ocr.md.

The approach follows the synthetic generator idea in https://github.com/thetahealth/mirobody-gen

14. Open decisions

  1. CPU OCR default: PP-StructureV3 or Docling. Both are allowed. We pick by the eval set (photo recall and table structure) and image size.
  2. Remote OCR endpoints. Not allowed (LAN or localhost only), because a remote endpoint sends health data off the box. Revisit only with a per-profile opt-in and a visible "this document goes to X" banner.
  3. Upload token for the iOS Shortcut and share target. The scope list covers MCP only. We need an upload-only REST token bound to one profile; it should not be an MCP scope.
  4. Optional "optimal" ranges. Not on the roadmap. Proposed: later, behind a cited YAML pack, off by default, never used for flags or status.
  5. Shipping the LOINC cut. We plan to vendor Mirobody's LOINC 2.83 content with the Regenstrief notice and the LOINC License, and its UCUM file under the UCUM License. Whether a subset in a public AGPL repo needs anything beyond the notice is unverified; the fallback is a download at install time.
  6. Paperless as the recommended single inbox. It already does IMAP, a consume folder and OCRmyPDF. Our own watched folder and IMAP may be enough as fallbacks.
  7. Identity check strictness. Some Spanish PDFs print only initials or a health card number. Do we let a profile store hashed identifiers (card number, sample id prefix) for matching?
  8. Codes marked † in 8.2 need checking against the LOINC release we ship before the alias table merges.

Rejected: a model that extracts structured values (an LLM or VLM that writes rows) inside the pipeline. OCR models in the opt-in ocr profile only return words and boxes; rules turn those into rows. OwnHealth has no built-in extraction model; pages the rules cannot read go to agent-assisted extraction (7.2) or manual entry. A community plugin could add one outside the core repo.