Personal baseline (usual level)¶
What it answers. Is the last result outside this person's own usual level? A population reference range is wide. A person's results usually stay in a much narrower band. A result can be inside the lab's range and still be far from the person's usual level.
Source. Coşkun A et al. Personalized reference intervals in laboratory medicine: a new model based on within-subject biological variation. Clin Chem 2021;67:374-384. https://doi.org/10.1093/clinchem/hvaa233
Formula. The rule baseline.personal in data/rules/pack/pack.yaml:
set point sp = mean of the n earlier results (3 <= n <= 5, the most recent ones)
half width = sp x z x √(CVa² + CVi²) x √(1 + 1/n) / 100
usual level = sp - half width to sp + half width
flag when |x - sp| > half width
x is the last result and z is 1.96. The CVs are the ones of the marker's RCV rule, so the same
EuBIVAS table feeds both. See rcv.md for the values and their DOIs. The √(1 + 1/n) term
widens the band when the set point rests on few results.
Which results count.
- Only earlier results with the same method and lab as the last result (see rcv.md). A result from another lab or method never moves the set point.
- At least 3 earlier results. With 2 or fewer there is no usual level and no flag.
- At most the 5 most recent earlier results, so the set point follows slow change and the state body stays small.
- Only the markers with an RCV rule: LDL cholesterol, hs-CRP, creatinine, ALT and TSH.
Order in the rule pack. lab_range, then rcv, then baseline, then trend. The first rule that
fires gives the marker its flag. A result outside the lab's printed range is flagged by the lab range,
and critical values stay the lab's own printed HH and LL.
Worked example. Carmen Ortega, creatinine at LabNorte (enzymatic): 0.80, 0.81 and 0.90 mg/dL, then 0.98 mg/dL. The set point is 0.8367 mg/dL. The half width is 0.8367 x 1.96 x √(1.1² + 4.4²) x √(1 + 1/3) / 100 = 0.0859 mg/dL. The usual level is 0.75 to 0.92 mg/dL, so 0.98 is outside it. The change from 0.90 to 0.98 is 8.9%, inside the creatinine RCV of 12.6%. So only the baseline sees this drift.
Where to read it.
- State body and its render: a flag with reason
BASELINE_OUT. The text names the usual level and the number of earlier results it rests on. Its sources are the earlier results and the last one. - REST:
GET /api/profiles/{p}/trend?code=...returnsstats.baselinewithset_point,low,high,n,outside,ruleandcite, ornullwhen there is no usual level yet. The band reads every earlier result, also the ones before thewindowthe chart asks for. - UI: the biomarker chart draws the usual level as a blue dashed band, with
n. The "Is the last change real?" card shows the band and says whether the last result is inside it.
Code. server/crates/ownhealth-rules/src/engine.rs (baseline_band, baseline). Tests:
server/crates/ownhealth-rules/tests/rule_pack_020.rs.